LG Electronics LGENBOX-01 Drums User Manual


 
17
Samples for Grounding
There is two of samples for grounding below.
Using a grounding wire
Using listed EGC
Determine the size of an external ground wire according to Article 690.46, NEC2014.
(Equipment grounding conductors smaller than 6 AWG shall be protected from physical damage.)
A grounding conductor with insulation or bare (no insulation) may be used, provided the terminations are reliably
available.
• Use equipment grounding conductors approved by Article 250.118, NEC2014.
Grounding
wire
AC junction box
grounding wire
Bonding
jumper
EGC
(ex. metal
rack)
LG AC module includes DC cables in the module’s internal wiring, so no grounding is required for DC input.
For equipment grounding, LG AC Module uses an external grounding equipment conductor. AC cable does not
provide a grounding conductor, grounding is provided only by the external connection to the module frame.
AC junction box