LG Electronics LGENBOX-01 Drums User Manual


 
29
4-4 Website
For more information on monitoring, please refer to AC module web server manual at
http://enervu.lg-solar.com/support/downloads.
To preventing set up error, it is recommended to set in the following order.
Default Mode Hawaii Mode
1)
Frequency 59.3 ~ 60.5 Hz 57.0 ~ 60.5 Hz
1)
In Hawaii mode, Transient Over-Voltage (TOV) mitigation is applied.
For details, refer to Chapter 6-3. Response to Abnormal Conditions.
Step 6. Setting System Configuration
Entering System Configuration, you can select Ethernet, NTP sever, web server or service type.
1
After running the app, click Time Synchronization to sync the time zone
of the gateway and web server .
2
If the IP address is assigned from the broadband router automatically .
Check that it has been assigned.
3
Network time protocol.
4
Enter URL, press Set button.
5
Check Web server connection after pressing the Set button.
When connected it will read, “Web Server has been connected”.
If not connected it will read, “Web Server is not connected”.
6
Determine the web server communication. If you do not accept the
personal information agreement, set OFF in order to disable the Ethernet
communication.
7
Next, press Set button to finish web server activation.
1
2
3
4
5
6
7
Set the grid configuration best suited to the installation area. PV system may malfunction otherwise.
CAUTION