Neumann.Berlin bcm 104 Microphone User Manual


 
66
Technical Data
Acoustical operating principle............................Pressure gradient transducer
Directional pattern......................................... Omnidirectional, cardioid, figure-8
Frequency range..................................................................................... 20 Hz...20 kHz
Sensitivity at 1 kHz into 1 kohm...........................................20/28/22 mV/Pa
1)
Rated impedance.................................................................................................200 ohms
Rated load impedance..................................................................................1000 ohms
Signal-to-noise ratio, CCIR
2)
(rel. 94dB SPL)...........................68/71/69 dB
1)
Signal-to-noise ratio, A-weighted
2)
(rel. 94dB SPL).............79/82/80 dB
1)
Equivalent noise level, CCIR
2)
..............................................................26/23/25 dB
1)
Equivalent noise level, A-weighted
2)
..........................................15/12/14 dB-A
1)
Maximum SPL for THD 0.5%
3)
................................................ 117 dB (cardioid)
Maximum SPL for THD 0.5% with preattenuation
3)
........................127 dB
Maximum output voltage...................................................................................390 mV
Dynamic range of the microphone amplifier, A-weighted .............105 dB
Supply voltage (P48, IEC61938)..........................................................48 V ± 4 V
Current consumption (P48, IEC61938)....................................................0.8 mA
Matching connector................................................................................................... XLR3F
Weight..................................................................................................................................500 g
Diameter..........................................................................................................................56 mm
Length............................................................................................................................ 200 mm
®
Neumann is a registered trademark of the Georg Neumann GmbH in certain countries.
measured in free-field conditions (IEC 60268-4), tolerance ±2dB
1)
Omnidirectional / cardioid / figure-8
2)
according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
3)
measured as equivalent el. input signal