Front Panel Operation
5-16
NOTE:
•
The rebuild priority determines how much of controller resources is
conducted when rebuilding a logical drive. The default setting of the
rebuild priority is “LOW.” Rebuild will have smaller impact on host I/O
access, but rebuild will take a longer time to complete. Changing the
rebuild priority to a higher level you will have a faster rebuild, but will
certainly increase the Host I/O response time. The default setting “LOW”
is recommended.
5.9 Viewing and Editing Logical Drives and
Drive Members
Press ENT for two seconds to enter the
Main Menu. Press ▼ or ▲ to select
"View and Edit Logical Drives..,” then
press ENT.
Press ▼ or ▲ to select the logical drive,
then press ENT.
Press ▼ or ▲ to select “View SCSI
Drives..", then press ENT .
Press ▼ or ▲ to scroll through the list
of member drives.
Deleting a Logical Drive
Press ENT for two seconds to enter the
Main Menu. Press ▼ or ▲ to select
"View and Edit Logical Drives," then
press ENT.
Press ▼ or ▲ to select a logical drive,
then press ENT.
Press ▼ or ▲ to select “Delete Logical
Drive," then press ENT .
Press ENT for two seconds to delete.
The selected logical drive has now
been deleted.
View and Edit
Logical Drives ↕
LG0 RAID5 DRV=3
2012MB GD SB=1
View SCSI Drives
..
View and Edit
Logical Drives ↕
LG0 RAID5 DRV=3
2012MB GD SB=1
Delete Logical
Drive ..
LG=0
Not Defined ?
C=1 I=0 1010MB
LG=0 LN SEAGATE