A SERVICE OF

logo

Front Panel Operation
5-16
NOTE:
The rebuild priority determines how much of controller resources is
conducted when rebuilding a logical drive. The default setting of the
rebuild priority is “LOW.” Rebuild will have smaller impact on host I/O
access, but rebuild will take a longer time to complete. Changing the
rebuild priority to a higher level you will have a faster rebuild, but will
certainly increase the Host I/O response time. The default setting “LOW”
is recommended.
5.9 Viewing and Editing Logical Drives and
Drive Members
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit Logical Drives..,” then
press ENT.
Press or to select the logical drive,
then press ENT.
Press or to select “View SCSI
Drives..", then press ENT .
Press or to scroll through the list
of member drives.
Deleting a Logical Drive
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit Logical Drives," then
press ENT.
Press or to select a logical drive,
then press ENT.
Press or to select “Delete Logical
Drive," then press ENT .
Press ENT for two seconds to delete.
The selected logical drive has now
been deleted.
View and Edit
Logical Drives
LG0 RAID5 DRV=3
2012MB GD SB=1
View SCSI Drives
..
View and Edit
Logical Drives
LG0 RAID5 DRV=3
2012MB GD SB=1
Delete Logical
Drive ..
LG=0
Not Defined ?
C=1 I=0 1010MB
LG=0 LN SEAGATE