ClearOne comm XAPTM 800 Musical Instrument User Manual


 
Appendices ~ Appendix E: Serial Commands
104
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
DFLTM - Default Meter
This command selects/reports the setting of the default meter.
Command form: DEVICE
DFLTM
[Channel] [Group] [Position]
Argument details
Name Description
Device 0–7 or * to select all units
DFLTM Command form
Channel 1–12
Group I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs
Position I, A, N, G, as applicable for group
(see Meter Type definitions, page 98)
Example:
#55 DFLTM 8 O A
On XAP 800 unit 5 (
#55
), the default meter
(
DFLTM
) is set to output (
O
)
8
after the gain adjustment (
A
).
DID - Device ID
This command selects/reports the device ID.
Command form: DEVICE
DID
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
DID Command form
Value 0–7 (select device ID)
Example:
#57 DID 0
On XAP 800 unit 7 (
#57
), the device ID (
DID
) is set to
0
.
DSPVER - DSP Version
This command reports the version of the DSP code in the unit. the version is a date
and time stamp. This command is read only.
Command form: DEVICE
DSPVER
[value]
Argument details
Name Description
Device 0–7 or * to select all units
DSPVER Command form
Value Null
Example:
#55 DSPVER
The XAP 800 unit 5 (
#55
) will return the DSP version
(
DSPVER
).