ClearOne comm XAPTM 800 Musical Instrument User Manual


 
117
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
MLINE - Mic/Line Adjust
This command selects/reports the setting of coarse gain adjustment on the input
channels 1-8. The three settings are 0dB, 25dB, and 55dB.
Command form: DEVICE
MLINE
<Channel>[Value]
Argument details
Name Description
Device 0–7 or * to select all units
MLINE Command form
Channel 1–8 (selects mic inputs)
Value 0 = 0dB (line level), 1 = 55dB, 2 = 25dB, Null = current level
Example:
#53 MLINE 1 2
On XAP 800 unit 3 (
#53
), the mic/line (
MLINE
)
setting for input
1
is 25dB (
2
).
MMAX - Maximum Number of Microphones
This command selects/reports the maximum number of microphones for each gating
group.
Command form: DEVICE
MMAX
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
MMAX Command form
Channel 1–4, A-D (gating groups)
Value 0 = Unlimited, 1–8 = Maximum number of mics
Null = Current maximum number of microphones
Example:
#52 MMAX A 4
On the XAP 800 unit 2 (
#52
), the max number of
mics (
MMAX
) in gating group
A
that are allowed to gate on at any one time is
4
.
MPASS - Modem Password
This command sets the current password setting for the unit when using modem
mode. The password must be entered in twice.
Command form: DEVICE
MPASS
[String]
Argument details
Name Description
Device 0–7 or * to select all units
MMAX Command form
String 0-12 characters, CLEAR = to clear the current password
Null to report the current password
Example:
#50 MPASS GENTNER
On XAP 800 unit 0 (
#50
), the modem
password (
MPASS
) is set to
GENTNER
.
Once the command is
given, the unit responds by
echoing back the
command, followed by "RE-ENTER
PASSWORD" string. The command
must then be re-entered exactly as
entered previously. Then, the
command will be echoed back,
followed by an "OK," indicating that
the password has been changed.