ClearOne comm XAPTM 800 Musical Instrument User Manual


 
51
System Configuration ~ Processing
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Post Compressor Gain Adjust the compressor gain with the gain slider or by using
the
and
buttons. The graph reflects the input/output decibel levels with the gain
setting you select.
Threshold Threshold determines the RMS level at which the compressor begins to
operate. The range is from -30 to +20dBu. Default is 0dBu.
Ratio Ratio changes the rate of compression applied to the input signal as the
signal exceeds the threshold level. The range is 1:1 to 1:20dB. Default is 1:1.
Attack Attack determines how quickly compression is enabled. It is calibrated in
milliseconds. The range is 0 to 100ms in .5ms steps. Default is 10ms.
Release Release determines how quickly compression is disabled. The range is
100ms to 2 seconds, in 5ms increments. Default is 500ms.
Input meter This peak meter shows the level of the signal as it enters the
compressor.
Compression meter This peak meter shows the instantaneous compression value
at a given time.
Filters
The Filter button on the selected Processing channel opens the Processing Filters
window. Here, you can configure all filters available in G-Ware: All Pass, Bessel,
Butterworth, CD Horn, High Pass, High Shelving, Linkwitz-Riley, Low Pass, Low
Shelving, Notch, and PEQ.
Figure 3.54. Processing Filters window