Parameters
34
Group 6: Ex Drawbar Set
Ex Drawbar Type 1-1 [-5...+24]
Specifies the pitch (in semitone steps) that will be as-
signed to the left bar (16') of the EX Drawbars (Drawbar
2) used by an EX program.
This setting will be used if the EX Edit mode Group 2 “Ex
Drawbar Type” parameter is set to 1.
-5: Five semitones lower than the 1' drawbar.
0: The 1' drawbar.
+24: Two octaves (24 semitones) above the 1' drawbar.
Ex Drawbar Type 1-2 [-5...+24]
Specifies the pitch (in semitone steps) that will be as-
signed to the second-from-left bar (5-1/3') of the EX
Drawbars (Drawbar 2) used by an EX program.
This setting will be used if the EX Edit mode Group 2 “Ex
Drawbar Type” parameter is set to 1.
-5: Five semitones lower than the 1' drawbar.
0: The 1' drawbar.
+24: Two octaves (24 semitones) above the 1' drawbar.
Ex Drawbar Type 1-3 [-5...+24]
Specifies the pitch (in semitone steps) that will be as-
signed to the third-from-left bar (8') of the EX Drawbars
(Drawbar 2) used by an EX program.
This setting will be used if the EX Edit mode Group 2 “Ex
Drawbar Type” parameter is set to 1.
-5: Five semitones lower than the 1' drawbar.
0: The 1' drawbar.
+24: Two octaves (24 semitones) above the 1' drawbar.
Ex Drawbar Type 1-4 [-5...+24]
Specifies the pitch (in semitone steps) that will be as-
signed to the right bar (4') of the EX Drawbars (Drawbar
2) used by an EX program.
This setting will be used if the EX Edit mode Group 2 “Ex
Drawbar Type” parameter is set to 1.
-5: Five semitones lower than the 1' drawbar.
0: The 1' drawbar.
+24: Two octaves (24 semitones) above the 1' drawbar.
Ex Drawbar Type 2-1 – Ex Drawbar Type 2-4 [-5...+24]
Specifies the pitches (in semitone steps) that will be
assigned to the EX Drawbars (Drawbar 2) used by an EX
program.
These settings will be used if the EX Edit mode Group 2
“Ex Drawbar Type” parameter is set to 2.
Ex Drawbar Type 3-1 – Ex Drawbar Type 3-4 [-5...+24]
Specifies the pitches (in semitone steps) that will be
assigned to the EX Drawbars (Drawbar 2) used by an EX
program.
These settings will be used if the EX Edit mode Group 2
“Ex Drawbar Type” parameter is set to 3.
Ex Drawbar Type 4-1 – Ex Drawbar Type 4-4 [-5...+24]
Specifies the pitches (in semitone steps) that will be
assigned to the EX Drawbars (Drawbar 2) used by an EX
program.
These settings will be used if the EX Edit mode Group 2
“Ex Drawbar Type” parameter is set to 4.
Pitches above the F#8 of the BX-3 will be “folded
back” to the octave below, so we suggest that you
play the lowest octave of the BX-3 to hear the pitches
you specify here.
Group 7: Utility
Program Mapper
This lets you change the correspondence between the BX-
3's program numbers and MIDI program numbers. Press
the [WRITE/ENTER] key and the editing screen will
appear. The BX-3's program number is shown in the left
of the display, and the MIDI program number at the right.
When you select an EX program, an “E” will be displayed
at the left of the program number.
Use the [√ ] [®] keys to select the BX-3 program number,
and use the [-] [+] keys to select the MIDI program
number.
Copy Swap Init
Copy (Copy Program)
This lets you copy a specified program. For details,
refer to “Copying a program” (p.22).
Swap (Swap Program)
This lets you exchange two specified programs. For
details, refer to “Swapping two programs” (p.22).
Init (Initialize)
This lets you return program or global settings to the
factory settings. For details, refer to “3. Restoring the
factory settings” (p.16).
Dump (MIDI Dump)
For details, refer to “MIDI data dump” (p.37).
Dump Program
Dumps the data for one specified program.
Dump All Program
Dumps the data for all programs.
Dump Global
Dumps the global data.
Dump All Data (Dump All Programs and Global data)
Dumps the data for all programs and global data.
Drawbar Scan
When the BX-3 receives MIDI control changes, the
drawbar registers will be modified, so that the sound may
no longer match the physical settings of the front panel
Drawbar 1 and 2 bars.
When you execute Drawbar Scan, BX-3 will re-read the
actual physical position of the Drawbar 1 and 2 settings,
and their values will be set in the drawbar registers.
Execute this when you want the settings of Drawbar 1
and 2 to be reflected in the sound. Since the control
changes for all drawbars will be transmitted via MIDI
when Drawbar Scan is executed, this is convenient when
you want to record a BX-3 performance on your se-
quencer.
Default DB Select (Default Drawbar Select)
[PRESET, 1, 2]
This controls which settings in the DRAWBAR SELECT
section will be active when the power is turned on.
1.Enter Global mode, and select this parameter.
2.Press the [WRITE/ENTER] key.
The display will allow you to specify your choice for
the upper DRAWBAR SELECT section.