Omega RD260A Recording Equipment User Manual


 
7 - 12
7.11 Setting Periodic Printout On/Off
The contents of the periodic printout can be selected from the following three:
ON1: Date/time, measured values, scale, and chart-feeding speed are printed.
ON2: Date/time and chart-feeding speed are printed.
OFF: No printout.
The default is set to ON1.
The relationship between the chart-feeding speed and the periodic printout interval is as
shown below.
Every 8 hours
Every 4 hours
Every 2 hours
Every 1 hour
Every 30 minutes
Every 20 minutes
Every 10 minutes
No printout
10 to 15mm/h
20 to 30mm/h
40 to 60mm/h
75 to 120mm/h
150 to 180mm/h
200 to 300mm/h
360 to 1500mm/h
1800mm/h or more
Chart Speed
Pen Model
Periodic Printout Interval
Every 8 hours
Every 4 hours
Every 2 hours
Every 1 hour
No printout
10 to 15mm/h
20 to 30mm/h
40 to 75mm/h
80 to 100mm/h
120mm/h or more
Chart Speed
Dot-printing Model
Periodic Printout Interval
SETTING PROCEDURE:
Enter the SET UP mode by turning ON the power while pressing and holding the [CH
UP] ( ENT) key until the SET UP display appears.
Use the [ ] key to select the display [ ]. Press the [ENT] key.
Use the [ ] key to select the display [ ]. Press the [ENT] key.
Select ON1, ON2or OFF using the [ ] key. Press the [ENT] key.
The display [ ] appear.
Before leaving the SET UP mode, you have to store your new settings. Use the [ ] key
to select the [ ] display, and press the [ENT] key.
Select [ ] to keep your new settings or [ ] to abort the settings, and
press the [ENT] key. After a few seconds, the OPERATION mode will appear.
NOTE If set, this printout appears on the chart with a certain regularity.