Turning Printing of Channel Numbers On/Off (Dot-printing model)
If turned on, this function prints each channel number next to the measured value at
approximately 25-mm intervals. The default value is ON.
Note that no channel number will be printed if the chart speed exceeds 120mm/h.
SETTING PROCEDURE:
Enter the SET UP mode by turning ON the power while pressing and holding the [CH
UP] ( ENT) key until the SET UP display appears.
Use the [ ] key to select the display [ ]. Press the [ENT] key.
Use the [ ] key to select the display [ ]. Press the [ENT] key.
Using the [ ] key, select either ON or OFF and then press the [ENT] key. The
display [ ] will appear.
Before leaving the SET UP mode, you have to store your new settings. Use the [ ] key
to select the [ ] display, and press the [ENT] key.
Select [ ] to keep your new settings or [ ] to abort the settings, and
press the [ENT] key. After a few seconds, the OPERATION mode will appear.