Sony OXF-R3 Music Mixer User Manual


 
2-4 Chapter 2 Powering the OXF-R3
Chapter 2 Powering the OXF-R3
2-2 OXF-R3 Shutdown Procedure
CAUTION:
Turn off or mute all monitor amplifiers connected to the OXF-R3.
Unless the OXF-R3 is to remain switched off for a prolonged period, it
will be more convenient to leave the Clock Synchronisation source
running.
2-2 OXF-R3 Shutdown
2-2-1 Shutdown Procedure
Note:
Note:
1. At the centre LCD screen on the OXF-R3 control surface, use the
appropriate softkey to select SYSTEM.
If necessary, retrace a number of steps through the screens hierarchy to reach this
point. Refer to the Screens Structure diagram in Chapter 5 for detailed
information on the screen page hierarchy.
2. On the SYSTEM screen page, click on SYSTEM SHUTDOWN on the
right side of the screen if it is displayed.
3. If SHUTDOWN is not displayed click on the ‘User field’ for a pop-up
and click on ADMIN. Enter the admin password (default is admin in
lower case) and click on OK. The field which includes SYSTEM
SHUTDOWN will then appear in the right side of the screen. Click on
it. A dialogue box will appear on the screen to request confirmation of
Shutdown and ask if current work should be saved. Press {ENTER} on
the Control Keyboard or click on OK.
4. The console now shuts down and power to the control surface can be
turned off but the STIF and UNIX windows on the Host Computer
monitor remain.
5. On the Host Computer, place the mouse cursor in the STIF window
and
Type: exit (case-sensitive) then press {RETURN}.
It is important to switch off the power to the control surface for a minimum of 10
seconds before attempting a re-start.
6. For a re-boot, turn on the power to the control surface again and follow
the Start-Up Procedure, in the previous section, from step 11. For a
complete power-down, continue with step 7 in this section.