Yamaha 01v DJ Equipment User Manual


 
258 Appendix A: General
01V—Owner’s Manual
Display Messages
Message Meaning
BULK: Byte Count Mismatch!
The byte count of the received Bulk Dump data is not cor-
rect.
BULK: Check Sum Error!
The check sum of the received Bulk Dump data is not cor-
rect.
BULK: Memory Protected!
The Bulk Dump data cannot be stored because the desti-
nation is write-protected.
DIGITAL IN Sync Error!
This warning message appears if the Digital Stereo Coaxial
In signal is not wordclock synchronized with the 01V.
Make sure that all digital equipment is wordclock synchro-
nized to a common wordclock source. See “Setting the
Wordclock” on page 209 for more information. This warn-
ing message can be disabled by turning off the DIGITAL IN
SYNC CAUTION option in the preferences (“Setting 01V
Preferences” on page 203).
For Effect2 Only.
The selected effect program can be recalled only to
Effect 2.
LOW BATTERY!!
The internal battery voltage is getting very low. Back up
the Setup data (“Bulk Dump” on page 232), and ask your
dealer to replace the battery.
Memory Protected
Cannot execute as selected scene memory is protected.
MIDI IN: Framing Error!
An incorrect signal may have been input to the MIDI IN.
MIDI IN: Data Overrun!
An incorrect signal may have been input to the MIDI IN.
MIDI: Rx Buffer Full!
The 01V is probably receiving too much MIDI data.
MIDI: Tx Buffer Full!
The 01V is probably transmitting too much MIDI data.
NO DATA
Cannot execute as no data has been stored.
Now Fading(Fade Time).
Local Control cannot be turned off while a mix-scene fade
is in progress (Fade Time).
OPTION IN Sync Error!
This warning message appears if the Option I/O input dig-
ital signal is not wordclock synchronized with the 01V.
Make sure that all digital equipment is wordclock synchro-
nized to a common wordclock source. See “Setting the
Wordclock” on page 209 for more information. This warn-
ing message can be disabled by turning off the DIGITAL IN
SYNC CAUTION option in the preferences (“Setting 01V
Preferences” on page 203).
Read Only
Cannot execute as selected scene memory is read only.
Selected channel: CHxx
CHxx is the selected channel.
Preparing to LOCAL OFF...
The MIDI Local Control function is preparing for use.
TO HOST: Framing Error!
An incorrect signal may have been input to the TO HOST
connector.
TO HOST: Data Overrun!
An incorrect signal may have been input to the TO HOST
connector.
TO HOST: Data Parity Error!
An incorrect signal may have been input to the TO HOST
connector.
TO HOST: Rx Buffer Full!
The 01V is probably receiving too much MIDI data at the
TO HOST connector.
TO HOST: Tx Buffer Full!
The 01V is probably transmitting too much MIDI data
from the TO HOST connector.
WRONG WORD CLOCK!
The received wordclock is not correct and the 01V cannot
synchronize correctly. Select a suitable wordclock, or use
the AUTO NAVIGATE function on the SETUP page 1.