Control Change Parameter Control 229
01V—Owner’s Manual
Control Change Parameter Control
When a MIDI Control Change message is received, a mix parameter is adjusted in
accordance with the parameter to Control Change assignment table. Likewise, when a
mix parameter is adjusted, the 01V transmits a Control Change message that can be
used to control another 01V or recorded to a MIDI sequencer for automated parameter
control.
Up to 114 mix parameters can be assigned to Control Changes 0 through 95 and 102
through 119 (Control Changes 96 through 101 are not used). Initially, 01V parameters
are assigned to Control Changes as listed in the “01V Parameter to Control Change
Table” on page 274, although these assignments can be edited on MIDI page 3. These
assignments are used for both transmission and reception, so if Control Change 10 is
assigned to channel fader 10, the 01V adjusts channel fader 10 when Control Change
#10 data is received, and transmits Control Change #10 when channel fader 10 is
adjusted. Assignment tables for use with the Yamaha Programmable Mixer 01 and
Yamaha 03D Digital Mixing Console are also provided.
In order for the 01V to receive and transmit MIDI Control Change messages, the Con-
trol Change Rx and Tx switches on MIDI page 1 must be turned on. See “MIDI Setup”
on page 224 for more information.
1. Use the [MIDI] button to locate MIDI page 3, as shown below.
2. Use the cursor buttons to select the CTL CHG. column, and then use the
PARAMETER wheel or [–1/DEC] and [+1/INC] buttons to select a Control
Change.
Since Control Changes 0 and 32 are used in conjunction with Program Change and
Bank Select messages, some MIDI sequencers may not record these Control Changes
correctly. In this case, set Control Changes 0 and 32 to NO ASSIGN.
3. Use the right cursor button to select the PARAMETER columns and the
PARAMETER wheel or [–1/DEC] and [+1/INC] buttons to select parame-
ters.
A parameter to Control Change assignment table is
provided on page 274. To reset the assignments to their
initial settings, use the cursor buttons to select the INI-
TIALIZE switch, and then press the [ENTER] button.
The dialog box shown here appears. Choose DEFAULT
to initialize.
The P.MIX 01 and 03D switches are used to configure Control Changes for use with the
Yamaha Programmable Mixer 01 or Yamaha 03D Digital Mixer. Parameter to Control
Change assignment tables for these are provided on page 277.
The current parameter to Control Change assignment table can be stored to an external
MIDI device, such as a MIDI data filer, using MIDI Bulk Dump. See “Bulk Dump” on
page 232 for more information.