Yamaha Digital Mixing Console DJ Equipment User Manual


 
280 MIDI Data Format
01V—Owner’s Manual
MIDI Data Format
1. TRANSMIT/RECEIVE DATA
1.1 CHANNEL MESSAGE
1.1.1 NOTE OFF (8n)
Reception
Received if [Rx CH] matches.
Used for EFFECT control. See below for details.
1.1.2 NOTE ON (9n)
Reception
Received if [Rx CH] matches.
Used for EFFECT control. See below for details.
A velocity of 0x00 is the same as NOTE OFF.
* Using Note data for EFFECT control
1: Dynamic Flange/Dynamic Phase/Dynamic Filter
When the SOURCE parameter is set to MIDI, Velocity will be used
together with Note On/Off to control the frequency width of Modu-
lation.
2: Freeze
When PLAY MODE is MOMENT or CONTINUE, a Note On mes-
sage will start play. However, this is only when the note number spec-
ified for MIDI TRG is received. Also, play will not occur if there is no
recorded data.
Regardless of the Note Number, a Note Off message will stop play if
PLAY MODE is MOMENT.
1.1.3 CONTROL CHANGE (Bn)
Reception
Received when [Control Change RX] is ON and the [Rx CH]
matches. However if [OMNI] is ON, this message is received regard-
less of the channel.
When [Control Change ECHO] is ON, this message will be echoed.
Parameters will be controlled according to the settings of the [control
assign table].
Control of specific faders can be disabled by the [midi fader control
input mute] settings.
If this message is received while the [control assign table] page is dis-
played, the cursor location will move to that control number.
Transmission
If [Control Change TX] is ON, this message is transmitted on the [Tx
CH] whenever a parameter specified in the [control assign table] is
operated.
If [Control Change ECHO] is ON, these messages will be merged
with the unit's own output while taking advantage of running status.
The control value is converted to the parameter value according to
the following equation.
C = 128 (byte parameter)
16384 (word parameter)
S = number of total possible steps for the parameter
C / S = X remainder Y
INT((Y+1)/2) = Z
If (MIDI DATA - Z) < 0 then -> param = 0
If ((MIDI DATA - Z)/X) > MAX then -> param = MAX
In other cases -> param =
INT((MIDI DATA -Z)/X)
1.1.4 PROGRAM CHANGE (Cn)
Reception
Received when [Program Change RX] is ON if the [Rx CH] matches.
However if [OMNI] is ON, this is received regardless of the channel.
This is echoed if [Program Change ECHO] is ON.
A scene memory will be recalled according to the settings of the [Pro-
gram change table].
Transmission
If [Program Change TX] is ON, this is transmitted on the [Tx CH]
channel when a scene memory is recalled.
If two or more program numbers have been assigned to the memory
number which was recalled, the lowest numbered program number
will be transmitted.
This message is echoed if [Program Change ECHO] is ON. (If a
memory number which is not specified in the [Midi Program
Change Assign Table] is recalled, the Parameter Change (Function
Call) described below will be transmitted.)
1.2 EXCLUSIVE MESSAGE (F0-F7)
1.2.1 MOTION CONTROL STATE (MCS)
MMC STOP/PLAY/FORWARD/REWIND/RECORD/
PAUSE
Transmission
In the [REMOTE-MMC] page, this is transmitted by key operations.
The [DEVICE NO.] specifies the transmission destination.
1.2.2 MOTION CONTROL PROCESS (MCP)
MMC LOCATE (target)
Transmission
In the [REMOTE-MMC] page, this is transmitted by key operations.
The [DEVICE NO.] specifies the transmission destination. (The ID
of the receiving device must be set.)
STATUS 1000nnnn 8n Note Off Message
DATA 0nnnnnnn nn Note No.
0vvvvvvv vv Velocity ( ignored)
STATUS 1001nnnn 9n Note On Message
DATA 0nnnnnnn nn Note No.
0vvvvvvv vv Velocity ( 1-127:On, 0:off)
STATUS 1011nnnn Bn Control Change
DATA 0ccccccc cc Control No. ( 0-95, 102-119)
0vvvvvvv vv Control Value (0-127)
STATUS 1100nnnn Cn Program Change
DATA 0nnnnnnn nn Program No. ( 0-127)
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command(mcc) sub-id
0ccccccc cc Command String
[1]:Stop
[2]:Play
[4]:Fast Forward
[5]:Rewind
[6]:Record Strobe
[9]:Pause
EOX 11110111 F7 End Of Exclusive
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command(mcc) sub-id
01000100 44 Locate
00000110 06 byte count
00000001 01 "target" sub command
0hhhhhhh hh hour
0mmmmmmm mm minute
0sssssss ss second
0fffffff ff frame
0sssssss ss sub-frame( only '0')
EOX 11110111 F7 End Of Exclusive