log devices
Configures severity levels for event logging on the Administration
Console.
Valid Minimum Abbreviation
log de
Important Considerations
■
You can set the console to log events for one or more of the four
severity levels.
■
To specify multiple severity levels, separate the levels with a comma
(for example,
warning
,
config
).
Options
Log Devices Examples (3500)
Prompt Description Possible Values [Default]
Levels for
console
Event logging severity level for
console output
■
error
■
warning
■
config
■
info
■
all
■
? (for a list of valid
severity levels)
–
Selected
levels
Whether selected event
logging for console output is
enabled or disabled
■
y (yes)
■
n (no)
y
Select menu option (log): devices
Select levels for console (error,warning,config,info|all|?): ?
Selectable values
error,warning,config,info
Select levels for console (error,warning,config,info|all|?): all
Enable the selected levels (n,y) [y]: y