Figure 2.9. Off Attenuation
Hold Time
This feature determines the length of time that a microphone remains On after the
microphone audio level drops below the gate ratio (Figure 2.10 below). Values range
from 0.18.0 seconds in one-tenth second increments. Default setting is 0.3. Setting
this value too low might cause the microphones to gate on and off too frequently
during brief pauses of speech. However, setting this value too high might cause too
many microphones to be on at one time.
Decay Rate
This feature determines how fast a microphone gates off after the hold time expires
(see Figure 2.11). Three options are available for this feature: slow (default),
medium, and fast.
Figure 2.10. Hold Time
Time
Figure 2.11. Decay Rate