ClearOne comm AP800 Musical Instrument User Manual


 
47
Appendices ~ Appendix F: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
LMO
This command changes or reports back the setting of the last
microphone on mode for each AP800.
[DEVICE] LMO <X>
Explanation
<X>
X=0 Parameter to set the mode to OFF
X=1 Parameter to set the mode to Microphone #1
X=2 Parameter to set the mode to Last Microphone On
X=Null Parameter to return the current mode
Return Values
The command will return the updated mode for the selected AP800
in the same format as the command.
LVL
This command reports back the level for a given channel.
[DEVICE] LVL <CH> <W>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified channel
CH= A-D Parameter to apply to the specified channel
<W>
W= I Parameter to specify an input meter
W= O Parameter to specify an output meter
W= A Parameter to specify an adaptive ambient
meter
Return Values
The command will return the input level of the channel in the same
format as the command.
MASTER
This command selects or returns the current mode of the
AP800 from the serial port.
[DEVICE] MASTER <X>
Explanation
<X>
X=1 Parameter to designate the AP800 as master-
single
X=2 Parameter to designate the AP800 as dual mixer
X=3 Parameter to designate the AP800 as slave
X=4 Parameter to designate the AP800 as master-
linked
X=Null Parameter to return the current mode
Return Values
The command will return the updated condition of the
mixer in the same format as the command.