ClearOne comm AP800 Musical Instrument User Manual


 
Appendices ~ Appendix F: Serial Commands
50
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
MPASS
This command sets the current password for modem mode.
Note: The default password is a carriage return (enter). If the
password is forgotten, it can be cleared back to a carriage
return via the front panel.
[DEVICE] MPASS <STRING>
Explanation
STRING can be any valid character combination up to eight
characters.
Return Values
Once the command is given, the unit responds by echoing back
the command.
MREF
This command changes or reports back which echo canceller
reference will be used by the microphone input.
[DEVICE] MREF <CH> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified microphone
channel
CH= * Parameter to apply command to all microphone
channels
<X>
X=1 Parameter to set the echo canceller reference to
EC reference 1
X=2 Parameter to set the echo canceller reference to
EC reference 2
X=Null Parameter to return the current state
Return Values
The command will return the updated condition of the echo
canceller reference in the same format as the command.
MTRX
This command programs or reports the configuration of where
an input is routed. The data is in a hex format. See the matrix
configuration table for specific routing information.
[DEVICE] MTRX <INPUT> <OUTPUTMIX>
Explanation
<INPUT>
INPUT=1-25 Selects the input to be routed to mix
outputs.
Input Input Word Assignment
1 Mic input
2 Mic input 2 post gate
3 Mic input 3 post gate
4 Mic input 4 post gate
5 Mic input 5 post gate
6 Mic input 6 post gate
7 Mic input 7 post gate
8 Mic input 8 post gate
9 Line input A
10 Line input B
11 Line input C
12 Line input D
1 Post gate 13 Subbus 1
14 Subbus 2
15 G-Link X
16 G-Link Y
17 G-Link Z
18 Mic input 1 pregate
19 Mic input 2 pregate
20 Mic input 3 pregate
21 Mic input 4 pregate
22 Mic input 5 pregate
23 Mic input 6 pregate
24 Mic input 7 pregate
25 Mic input 8 pregate