53
Appendices ~ Appendix F: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
NOM
This command changes or reports back state of NOM
attenuation for each channel.
[DEVICE] NOM <CH> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified direct
output channel
CH= A-D Parameter to apply to the specified line
output
<X>
X=0 Parameter to set NOM attenuation to OFF
X=1 Parameter to set NOM attenuation to ON
X=Null Parameter to return the current state of NOM
attenuation
Return Values
The command will return the updated condition (On=1,
Off=0) of NOM attenuation for the selected channel in the
same format as the command.
OFFA
This command changes or reports back the setting of Off
attenuation.
[DEVICE] OFFA <X>
Explanation
<X>
X=0-50 Parameter to set the amount of off
attenuation (in dB)
X=Null Parameter to return the current value of off
attenuation
Return Values
The command will return the updated value of off
attenuation in the same format as the command.
PAA
This command selects or returns the current status of the PA
adaptive mode.
[DEVICE] PAA <X>
Explanation
<X>
X=0 Parameter to select PA adaptive mode to OFF
X=1 Parameter to select PA adaptive mode to ON
X=Null Parameter to return the current mode
Return Values
The command will return the updated condition (On=1, Off=0) of
the PA adaptive mode in the same format as the command.