ClearOne comm AP800 Musical Instrument User Manual


 
Appendices ~ Appendix F: Serial Commands
52
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
MUTE
This command changes or reports the state of mute for a given
channel.
[DEVICE] MUTE <CH> <W> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified microphone
channel
CH= A-D Parameter to apply to select the line channel
CH= 1-2 Parameter to apply to select the subbus channel
CH= * Parameter to apply to all microphone channels
<W>
W=S Parameter to set subbus
W=I Parameter to set input
W=O Parameter to set output
<X>
X=0 Set mute to OFF
X=1 Set mute to ON (mute the selected channel)
X=2 Parameter to toggle the state from one state to the
other (regardless of current state)
X=NULL Report the current state of mute for the selected
channel
Return Values
The command will return the mute status (On=1, Off=0) in the
same format as the command.
NLP
This command changes or reports back the state of the
nonlinear processing for a microphone.
DEVICE] NLP <CH> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified
microphone channel
CH= * Parameter to apply command to all microphone
channels
<X>
X=0 Parameter to set the state to OFF
X=1 Parameter to set the state to soft
X=2 Parameter to set the state to medium
X=3 Parameter to set the state to aggressive
X=Null Parameter to return the current state
Return Values
The command will return the updated condition (0=Off,
1=Soft, 2=Medium, 3=Aggressive) of the nonlinear
processing in the same format as the command.