ClearOne comm AP800 Musical Instrument User Manual


 
Appendices ~ Appendix F: Serial Commands
42
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
BAUD
This command selects or returns the baud rate for the RS-232
port on the AP800.
[DEVICE] BAUD <X>
Explanation
<X>
X=1 Selects 9,600 baud (bps) rate
X=2 Selects 19,200 baud (bps) rate
X=3 Selects 38,400 baud (bps) rate
X=Null Parameter to return the baud (bps) rate
Return Values
The command will return the updated condition (1=9,600
baud, 2=19,200 baud, 3=38,400 baud) of the baud rate in the
same format as the command.
CHAIRO
This command changes or reports back the state of the
chairman override for a microphone channel.
[DEVICE] CHAIRO <CH> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified
microphone channel
CH= * Parameter to apply command to all
microphone channels
<X>
X=0 Parameter to set the state to OFF
X=1 Parameter to set the state to ON
X=2 Parameter to toggle the state from one
state to the other (regardless of current state)
X=Null Parameter to return the current state
Return Values
The command will return the updated condition (On=1, Off=0)
of the chairman override in the same format as the command.
DECAY
This command changes or reports back the setting of the
decay rate for a given AP800.
[DEVICE] DECAY <X>
Explanation
<X>
X=1 Parameter to set the decay rate to slow
X=2 Parameter to set the decay rate to medium
X=3 Parameter to set the decay rate to fast
X=Null Parameter to return the current decay rate
Return Values
The command will return the updated decay rate for the
selected AP800 in the same format as the command.
DFLTM
This command changes and reports back the status of the
default meter.
[DEVICE] DFLTM <CH> <W>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified channel
CH= A-D Parameter to apply to the specified channel
CH= Null Parameter to return the current state of the
default meter
<W>
W= I Parameter to specify an input channel
W= O Parameter to specify an output channel
Return Values
The command will return the current default meter in the
same format as the command.