ClearOne comm AP800 Musical Instrument User Manual


 
Appendices ~ Appendix F: Serial Commands
46
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
GMODE
This command changes or reports back the gating mode for a
microphone.
[DEVICE] GMODE <CH> <X>
Explanation
<CH>
CH= 1-8 Parameter to apply to the specified microphone
channel
CH= * Parameter to apply command to all microphone
channels
<X>
X=1 Parameter to set the state to AUTO
X=2 Parameter to set the state to MANUAL ON
X=3 Parameter to set the state to MANUAL OFF
X=4 Parameter to set the state to OVERRIDE ON
X=5 Parameter to set the state to OVERRIDE OFF
X=Null Parameter to return the current state
Return Values
The command will return the updated condition of the gating
in the same format as the command.
GRATIO
This command changes or reports back the setting of the gate
ratio.
[DEVICE] GRATIO <X>
Explanation
<X>
X=0-50 Parameter to set the Gate Ratio (in dB)
X=Null Parameter to return the current gate ratio
Return Values
The command will return the updated gate ratio (050) in the
same format as the command.
HOLD
This command changes or reports back the setting of the hold
time.
[DEVICE] HOLD <X>
Explanation
<X>
X=100-8000 Parameter to set the hold time (in
milliseconds)
X=Null Parameter to return the current hold time
Return Values
The command will return the updated hold time in the same
format as the command.
LFP
This command locks, unlocks, or returns the current state of
the front panel from the serial port.
[DEVICE] LFP <X>
Explanation
<X>
X=0 Parameter to unlock the front panel
X=1 Parameter to lock the front panel
X=2 Parameter to toggle the state from one state to
the other (regardless of current state)
X=Null Parameter to return the current state of the
front panel
Return Values
The command will return the updated condition of the front
panel.