GE IC3645SP4U400N3 Musical Instrument User Manual


 
DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 22
January 2000
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-05
Start switch fails to close. This status code will be displayed when P7 is less
than 2.5 volts and P3 is less than 60% of battery volts.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective start switch circuit.
=Check start switch to insure closure when
accelerator is depressed.
=Check for open circuit or loose connections in
wiring from brake switch to start switch and
from P3 to start switch.
Defective accelerator switch.
=Check accelerator switch potentiometer for
proper operation and ohmic value.
KEY
SWITCH
REVERSE SW.
FORWARD SW.
SEAT SWITCH
L
START SW.
P7
ACCPOT
P1 P2 P3
P17 P5P4P6
NEG
KEY SWITCH
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-06
Accelerator depressed with no
direction selected.
This status code will be displayed when P4 and P5
are less than 60% of battery volts, and P7 is less than
2.5 volts.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Accelerator pedal is depressed before closing
forward or reverse directional switch.
=Status code will disappear when directional
switch is closed or when accelerator pedal is
released.
Defective directional switch
=Check forward or reverse switch to insure
closure when direction is selected.
Open circuit between directional switch(es) and
battery positive or between directional switch(es)
and P4 or P5.
=Check all control wires and connections shown
in Trouble Shooting Diagram.
KEY
SWITCH
REVERSE SW.
FORWARD SW.
SEAT SWITCH
L
START SW.
P7
ACCPOT
P1 P2 P3
P17 P5P4P6
NEG
KEY SWITCH