46
Table 7 GVG100 Supported Analog Controls
Name MLE/Keyer Byte Code Notes
Key Clip Keyer 0x0A
Key Gain Keyer 0x0B
Vert. Position MLE 0x11
Horz. Position MLE 0x12
Key Matte Fill Hue MLE 0x14 Key mattes not supported
Pattern Size MLE 0x15
Chroma Key Hue Keyer 0x17 Write not supported
Key Matte Border Hue Keyer 0x18 Key mattes not supported
Key Matte Border Sat Keyer 0x19 Key mattes not supported
Key Matte Border Lum Keyer 0x1A Key mattes not supported
Key Matte Fill Lum Keyer 0x1B Key mattes not supported
Aspect MLE 0x1C Aux MLEs not supported
Border Softness MLE 0x1D Aux MLEs not supported
Border Width MLE 0x1E Aux MLEs not supported
Key Matte Fill Sat Keyer 0x1F Key Mattes not supported
Rotate X — 0x20 Not supported
Rotate Y — 0x21 Not supported
Rotate Z — 0x22 Not supported
3D Position X — 0x23 Not supported
3D Position Y — 0x24 Not supported
3D Position Z — 0x25 Not supported
3D Border Softness — 0x26 Not supported
3D Border Width — 0x27 Not supported
Key Clip Keyer 0x08 DSKs
Key Gain Keyer 0x09 DSKs
Table 8 GVG100 Supported Lamps
Name MLE/Keyer Byte Code Notes
Program Bus 0-9 MLE 0x00-0x09 Turning OFF results in a protocol error.
Program Bus On Air MLE 0x0A Turning OFF results in a protocol error.
Autotrans MLE 0x0B
Key Dissolve Keyer 0x0C
Key Cut Keyer 0x0D
Wipe Trans MLE 0x0E
Dissolve Trans MLE 0x0F
Preset Bus 0-9 MLE 0x10-0x19 Turning OFF results in a protocol error.
Preset Bus On Air MLE 0x1A Turning OFF results in a protocol error.
Aspect On
MLE 0x1B Always on. Turning OFF results in a
protocol error.