5 - 75
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting Value, setting range
Value set with peripheral device
Setting value buffer memory
address
Servo amplifier setting invalid
(
: Valid, : Invalid)
MR-J3-B
Value set with PLC program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
0
1: is used to set up the setting
value.
(Hexadecimal)
Machine resonance
suppression filter 2
Notch depth selection
Notch width selection
H
0000
H
30134 30334 30534 30734
100 to 18000 3141 30136 30336 30536 30736
1 to 1000 1000 30137 30337 30537 30737
1 to 1000 1000 30138 30338 30538 30738
2: The PB
corresponds with servo parameter No. of the servo amplifier.
3: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75MH), then switch it
on again to make that parameter setting valid.