1 - 21
MELSEC-Q
1 PRODUCT OUTLINE
QD75MH Manual pulse generator
The QD75MH and manual pulse generator communicate the following data via the
external device connection connector.
(The manual pulse generator should be connected to an external device connection
connector for axis 1 or for axes 1 and 2.)
Direction
Communication
QD75MH
Manual pulse generator Manual pulse generator QD75MH
Pulse signal –
• Manual pulse generator A-phase
• Manual pulse generator B-phase
QD75MH External signal
The QD75MH and external signal communicate the following data via the external
device connection connector.
Direction
Communication
QD75MH
External signal External signal QD75MH
Control signal –
•
Forced stop input signal
•
Upper/lower limit signal
•
External command signal/switching
signal
•
Stop signal
•
Near-point dog signal