! Open cap.
! Top-up with hydraulic oil.
Oil types: See "Technical Data".
! Close cap.
! Check the hydraulic oil level.
! Tilt the seat back.
Checking and topping up cooling
water
! Open unit cover.
The cooling water level must be
between the "min." and "max."
marks.
Top up with cooling water if the
cooling water level is below the
"min." mark.
Do not fill up beyond "max.".
! Open cap
! Top up cooling water up to the
"max." mark.
! Close cap.
! Close unit cover.
Checking cooler hose and hose
clamps
! Open unit cover.
! Check whether the hose clamps
are loose, retighten, if necessary.
! Check cooler hose and hose
clamps for damage.
Note:
If a cooler hose or a hose clamp is
damaged the concerned part must
be immediately repaired or
replaced.
! Close unit cover.
Check the air cleaner
! Open unit cover.
! Open quick-acting clamp.
! Take off the lid.
! Take out filter cartridge.
! Use a new filter cartridge.
! Place on the sealing cover.
! Fasten cap with quick-action clamp.
! Close unit cover.
Check and re-adjust V-belt
The engine takes approx. 3...4 s to
run down after being shut off.
Never enter operating area during
this period!
! Open unit cover.
In the middle between the
crankshaft and the alternator the V-
belt must yield by approx. 7-9 mm
at a pressure of 100 N (weight of
10 kg).
! Unscrew screws at the alternator.
! Adjust alternator so that the V-belt
has the required tension.
! Retighten the screws at the
alternator.
! Close unit cover.