M-Audio Axiom Pro Electronic Keyboard User Manual


 
|
44
Axiom Pro User Guide
Edit Mode > Zones > Data
press 4
press
soft-key 4,
“DATA”
You can open the Data page for a Zone by entering Edit Mode, selecting the Zone for editing, and then pressing soft-key 4
(Data). This gives access to additional parameters relating to the operation of an individual zone.
Parameter: Channel
Value Range: Global, 1-16
This parameter sets the MIDI output channel of the selected zone. The parameter can be set in the
following ways:
•Global This sets the MIDI channel for the selected zone to the same channel as specified
on the Edit > Global page.
•1-16 This sets the MIDI channel for the selected zone to a channel between 1 and 16.
Parameter: Octave
Value Range: -4 through +4
This parameter shifts the octave range of the selected keyboard zone either up or down. Note
thatthisparameterworksinconjunctionwithanyglobalshiftyoumayhavesetusingthe“Octave”
parameter on the Edit Mode > Global page. For example, if you have set the global octave shift to
“+1” and set this parameter to “+2” your selected zone will be shifted upward by three octaves.
Parameter: Transp.
Value Range: - 12 through +12
This parameter simultaneously shifts all keys in the selected keyboard zone up to 12 semitones in
eitherdirection.Notethatthisparameterworksinconjunctionwithanyglobaltranspositionyoumay
have set using the “Transp.” parameter on the Edit Mode > Global page. In other words, if you have
set the global transposition shift to “+1” and set this parameter to “+2”, your selected zone will be
transposed upward by three semitones.