M-Audio Axiom Pro Electronic Keyboard User Manual


 
|
46
Axiom Pro User Guide
Edit Mode > MIDI
press 4
This page contains a variety of options relating to MIDI.
Parameter: SysEx
Value Range: Off, O, A, A&O, B, B&O, A&B, All
SysEx messages can be transmitted on any combination of Axiom Pro ports:
• A Axiom Pro 61
12
USB A
• B Axiom Pro 61
12
USB B
• O Axiom Pro 61
12
MIDI Out (External MIDI port)
• All MIDI data is transmitted on all ports
• Off MIDI data is not transmitted
NOTE: SysEx messages are not MIDI channel specific, instead, a “Device ID”
number is used. If a SysEx message is sent out of a specific Axiom Pro MIDI
port, all connected devices (or software) will receive that data. More info about
SysEx transfers and Device IDs can be found below.
Parameter: DevID
Value Range: 0-127
This parameter sets the “Device ID” code used when transmitting SysEx messages from Axiom Pro.
The default value is 127.
The default setting of 127 lets your Axiom Pro respond to all incoming SysEx messages that are
compatible with Axiom Pro controllers. However, if you change the Device ID to any other value,
your Axiom Pro will only respond to SysEx messages that contain the same Device ID number. This
is useful in situations in which multiple Axiom Pro controllers are connected to your sequencer but
you would like to send SysEx information to a specific controller with a unique Device ID number.
12
The 25 and 49-note versions of Axiom Pro will appear as “Axiom Pro 25” and “Axiom Pro 49” respectively.