Roland 5 Electronic Keyboard User Manual


 
Europa User Guide
Europa User GuideEuropa User Guide
Europa User Guide
Europa MIDI Implementation
Europa MIDI Implementation Europa MIDI Implementation
Europa MIDI Implementation
Page 67
Dump preset (001 on bits 6-4):
00h-2fh – Dump preset A
AA
A-
--
-1
11
1 through D
DD
D-
--
-8
88
8 in flash
30h-7eh – Invalid (command will be ignored)
7fh - Dump preset edit
Dump sequence (011 on bits 6-4):
00h - Dump upper arpeggiator rhythm/sequence
01h - Dump lower arpeggiator rhythm/sequence
Figure 20 - Command 04h - Dump block request command
Requests a sequence, patch or patch block, preset or preset block dump from Europa. It responds with
one or more write block commands (05h). In the case where multiple presets or patches are dumped,
multiple write block commands will be sent – one for each patch or preset. Europa delays 70 milliseconds
between each write block command transmitted because of this command. This ensures the patches
and/or presets will be properly restored when played back to the Jupiter 6, as this delay is required for
writing to Europa’s flash memory.
Byte # Value Description
0
05h Write block – patch, preset, or sequence
1
Bitwise Bit 7 Unused – set to 0
Bits 6-4 Block type to write:
000 – Patch
001 – Preset
010 – Reserved – not valid
011 – Arpeggiator step rhythm/sequence
100-111 – Not valid - Command will be ignored
Bits 3-0 Unused – set to 0 (other values will invalidate the
message and it will be ignored.
2-n
Depends on the
block type
See tables below for appropriate patch, preset, or sequence dump
Figure 21 - Command 05h - Write block command
Instructs Europa to store a patch, preset, or sequence block in flash or edit buffer. Note that any patch or
preset written to flash must delay at least 70 milliseconds afterward to give time for Europa to write to
internal flash, otherwise any subsequent command for that time period will be ignored/dropped!
Depending upon byte 1 of the command 05h data stream, one of the following three tables will be
applicable:
Byte # Valid
range
Name
Description
2 0-47,
126-127
Patch number Place to store patch #0-47 are patch flash positions
A
AA
A-
--
-1
11
1 through F
FF
F-
--
-8
88
8. 126=Lower patch edit,
127=Upper patch edit (used in WHOLE
WHOLE WHOLE
WHOLE mode)
3 0-16 Patch name length Length of patch’s name. Can be up to 16 ASCII
characters
4-19 0-127 Patch name Patch’s name (in ASCII). This is actually a variable
length field and is only as long as the data in byte #
3.
20 0-127 LFO 1
LFO 1LFO 1
LFO 1 Rate Set LFO 1
LFO 1LFO 1
LFO 1’s rate
21 0-127 LFO 1
LFO 1LFO 1
LFO 1 Delay Set LFO 1
LFO 1LFO 1
LFO 1’s delay time
22 0-127
VCO MOD LFO
VCO MOD LFOVCO MOD LFO
VCO MOD LFO
Set LFO 1
LFO 1LFO 1
LFO 1’s effect on VCO
VCOVCO
VCO