50
Other Features
Change this parameter if the indicator on an amp connected to an AMP CONTROL
jack (1 or 2) does not correspond to the ON indicator (indicator lit) on the FC-300.
1
Press PARAMETER [ ] [ ] to select “SYS:AMP 1 Pol.” or
“SYS:AMP 2 Pol.”
2
Press VALUE [ ] [ ] to make the setting.
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Follow the steps below to specify whether a pedal being connected to an EXP
PEDAL/CTL jack (on the rear panel) is a control pedal or an expression pedal. This
setting needs to be made individually for each jack.
1
Press PARAMETER [ ] [ ] to select “SYS:E3/C3 Type”, “SYS:E4/C5 Type”
or “SYS:E5/C7 Type.”
2
Press VALUE [ ] [ ] to make the setting.
3
When you’ve finished making the settings, press [UTILITY] or [EXIT].
Setting the Polarity of the AMP CONTROL Jacks
Value
Explanation
NORMAL
The parameter is set to the factory setting.
INVERT Actual operation is the reverse of that indicated by the FC-300’s ON/OFF
indicator.
Determining the Role of an EXP PEDAL/CTL Jack
Value
Explanation
EXP PEDAL
The jack will be used for connecting expression pedals.
Connect a Roland EV-5 or BOSS FV-500L or FV-500H.
CTL The jack will be used for connecting control pedals.
Connect a BOSS FS-5U or FS-6.
FC-300_e1.book 50 ページ 2007年4月24日 火曜日 午前10時10分