Roland RD-300SX Musical Instrument User Manual


 
48
Connecting External MIDI Devices
3.
Press [INC] or [DEC] to change the parameter values.
Pressing [INC] and [DEC] simultaneously switches the settings
value to “--- (OFF).” When this setting is “--- (OFF),” program
numbers or bank select messages will not be transmitted.
When setting the LOWER zone, set [LOWER SELECT] to ON.
Now, try using an external sequencer to record your music onto
multiple tracks, and then play back the recorded performance.
fig.04-03
1.
Before starting the connection procedure, make sure that
the power to all devices has been turned off.
2.
After reading “Connecting the RD-300SX to External
Equipment” (p. 12), connect an audio device/system or
headphones.
3.
Connect the external MIDI sequencer with the MIDI cable as
shown in the figure above.
4.
As described in “Turning On the Power” (p. 13), turn on the
power of each device.
When recording to an external sequencer, it is convenient if you set
MIDI TX Mode to Mode2. When using this function, you can get the
most suitable settings for recording the RD-300SX’s data to an
external sequencer, without having to make all the Part and channel
settings.
For more detailed information on how to make the settings, refer to
“Setting the MIDI Tx Mode”
(p. 46).
Use the following procedure when recording to an external
sequencer.
1.
Turn on the external sequencer’s Thru function and turn off
the RD-300SX’s local control.
For details, refer to the section
“Switching Local Control On
and Off”
(p. 46).
Refer to your sequencer owner’s manual for instructions on
how to carry out this procedure.
2.
Select the Setup for the performance to be recorded.
For instructions on selecting the Setup, refer to p. 34.
3.
Use the procedure described in the previous section
“Settings for Recording” to make the MIDI Tx Mode settings
to Mode2.
4.
Begin recording with the external sequencer.
5.
Bulk Dump the Setup.
Transmit the contents of the selected Setup to the external
sequencer.
For instructions on carrying out this operation, refer to
“Transferring Setups to External Devices (Setup Bulk
Dump)”
(p. 44).
6.
Perform on the RD-300SX.
7.
When the performance is finished, stop recording with the
external sequencer.
Recording is now complete.
You can then listen to the recorded performance by playing it
back on the external sequencer.
Parameter
Tx
Value
Bank Select MSB
CC 00 0–127, --- (OFF)
Bank Select LSB CC 32 0–127, --- (OFF)
Program Change
Program
Change
0–127, --- (OFF)
Pan CC10 L64–0–63R, --- (OFF)
Reverb Send CC91 --- (OFF), 0–127
Chorus Send CC93 --- (OFF), 0–127
Key Transpose --- -48–0– +48
MIDI Ch --- 1–16
Recording RD-300SX
Performances to an
External MIDI Sequencer
Connecting to an External
Sequencer
MIDI IN MIDI OUT
MIDI IN MIDI OUT
RD-300SX
MIDI Sequencer
Settings for Recording
Recording the Performance
RD-300SX_e.book 48 ページ 2005年4月20日 水曜日 午後3時40分