Yamaha WH39070 Music Mixer User Manual


 
Effects Parameters
242
LS9-16/32 Owner’s Manual
MULTI FILTER
Two input, two output 3-band multi-filter (24 dB/octave).
FREEZE
One input, two output basic sampler.
STEREO REVERB
Two input, two output stereo reverb.
M. BAND DYNA.
Two input, two output 3-band dynamics processor, with
individual solo and gain reduction metering for each band.
Parameter Range Description
TYPE 1 LPF, HPF, BPF
Filter 1 type: high pass, low pass,
band pass
FREQ. 1 28.0 Hz–16.0 kHz Filter 1 frequency
LEVEL 1 0–100 Filter 1 level
RESO. 1 0–20 Filter 1 resonance
TYPE 2 LPF, HPF, BPF
Filter 2 type: high pass, low pass,
band pass
FREQ. 2 28.0 Hz–16.0 kHz Filter 2 frequency
LEVEL 2 0–100 Filter 2 level
RESO. 2 0–20 Filter 2 resonance
TYPE 3 LPF, HPF, BPF
Filter 3 type: high pass, low pass,
band pass
FREQ. 3 28.0 Hz–16.0 kHz Filter 3 frequency
LEVEL 3 0–100 Filter 3 level
RESO. 3 0–20 Filter 3 resonance
Parameter Range Description
REC MODE MANUAL, INPUT
In MANUAL mode, recording is
started by pressing the REC and
PLAY buttons. In INPUT mode,
Record-Ready mode is engaged by
pressing the REC button, and
actual recording is triggered by the
input signal.
REC DLY
–1000 to +1000
ms
Recording delay. For plus values,
recording starts after the trigger is
received. For minus values, record-
ing starts before the trigger is
received.
PLY MODE
MOMENT,
CONTI., INPUT
In MOMENT mode, the sample
plays only while the that the PLAY
button is pressed. In CONT mode,
playback continues once the PLAY
button has been pressed. The
number of times the sample plays
is set using the LOOP NUM param-
eter. In INPUT mode, playback is
triggered by the input signal.
TRG LVL –60 to 0 dB
Input trigger level (i.e., the signal
level required to trigger recording
or playback)
TRG MASK 0–1000 ms
Once playback has been triggered,
subsequent triggers are ignored for
the duration of the TRG MASK
time.
START
*1
*1. 0.0–5941.0 ms (fs=44.1 kHz), 0.0 ms–5458.3 ms (fs=48 kHz)
Playback start point in milliseconds
END
*1
Playback end point in milliseconds
LOOP
*1
Loop start point in milliseconds
LOOP
NUM
0–100 Number of times the sample plays
PITCH
–12 to +12 semi-
tones
Playback pitch shift
FINE –50 to +50 cents Playback pitch shift fine
MIDI TRG OFF, C1–C6, ALL
PLAY button can be triggered by
using MIDI Note on/off messages.
START
[SAMPLE]
0–131000 Playback start point in samples
END
[SAMPLE]
0–131000 Playback end point in samples
LOOP
[SAMPLE]
0–131000 Loop start point in samples
Parameter Range Description
REV TIME 0.3–99.0 s Reverb time
REV TYPE
Hall, Room, Stage,
Plate
Reverb type
INI. DLY 0.0–100.0 ms Initial delay before reverb begins
HI. RATIO 0.1–1.0 High-frequency reverb time ratio
LO. RATIO 0.1–2.4 Low-frequency reverb time ratio
DIFF. 0–10
Reverb diffusion (left–right reverb
spread)
DENSITY 0–100% Reverb density
E/R BAL. 0–100%
Balance of early reflections and
reverb (0% = all reverb, 100% =
all early reflections)
HPF
THRU, 21.2 Hz–
8.00 kHz
High-pass filter cutoff frequency
LPF
50.0 Hz–16.0 kHz,
THRU
Low-pass filter cutoff frequency
Parameter Range Description
LOW GAIN –96.0 to +12.0 dB Low band level
MID GAIN –96.0 to +12.0 dB Mid band level
HI. GAIN –96.0 to +12.0 dB High band level
PRESENCE –10 to +10
For positive values, the thresh-
old of the high band is low-
ered and the threshold of the
low band is increased. For
negative values, the opposite
will occur. When set to 0, all
three bands are affected the
same.
L–M XOVR 21.2 Hz–8.00 kHz Low/mid crossover frequency
M–H XOVR 21.2 Hz–8.00 kHz Mid/high crossover frequency
SLOPE –6 dB, –12 dB Filter slope
CEILING –6.0 dB to 0.0 dB, OFF
Specifies the maximum output
level
CMP. THRE –24.0 dB to 0.0 dB Compressor threshold
CMP. RAT 1:1 to 20:1 Compressor ratio
CMP. ATK 0–120 ms Compressor attack
CMP. REL
*1
Compressor release time
CMP. KNEE 0–5 Compressor knee
CMP. BYP OFF/ON Compressor bypass
LOOKUP 0.0–100.0 ms Lookup delay
EXP. THRE –54.0 dB to –24.0 dB Expander threshold
EXP. RAT 1:1 to :1 Expander ratio
EXP. REL
*1
*1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz)
Expander release time
EXP. BYP OFF/ON Expander bypass
LIM. THRE –12.0 dB to 0.0 dB Limiter threshold
LIM. ATK 0–120 ms Limiter attack
LIM. REL
*1
Limiter release time
LIM. KNEE 0–5 Limiter knee
LIM. BYP OFF/ON Limiter bypass