e
date_nunitsago – (optional) specifies the number of units before the time of report
generation of the last day of the time range.
0
The last day of the time range will be the first day of the unit
following the current unit at the time of report generation
1
The last day of the time range will be the first day of the current
unit at the time of report generation (default)
<number>
The time range will extend to the end of this number of full units
before the time of report generation
stime – specifies the time of day at which the time range starts.
<HH>:<mm>
The time, with <HH> being the hour in the 24-hour clock and <mm>
being the minutes
etime – specifies the time of day at which the time range ends.
<HH>:<mm>
The time, with <HH> being the hour in the 24-hour clock and <mm>
being the minutes
Applying a time-of-day mask to the time range
If the time range is longer than a day, you may wish to restrict it to just certain times
on each day. You can select only working hours or only non-working hours, for
example.
Note that if a long-term report has a configured time zone or mask, this parameter will
have no effect.
timemask – specifies an inclusive mask to apply the to time range. To specify multiple
inclusive masks, include a parameter name and value in the URL for each mask.
<day1>-<day2>/<time1>-<time2>
The range of weekdays and the
times on those weekdays to
include in the mask with a weekday
being one of SUN, MON, TUE, WED,
THU, FRI or SAT, day2 coming on
or after day1 in the list above, a
time being in the 24-hour form
hh:mm, and time2 being after
time1
timemask_exclude=true – specifies that the supplied time masks are excluded from
the time range rather than included in it.