Fluke Recording Equipment Recording Equipment User Manual


 
User’s Guide – version 3.1.3 NetFlow Tracker
51
d
stappl – specifies an acceptable destination IP application. Format as for srcappl
above.
dstappl_exclude=true – specifies that the supplied destination applications are
excluded rather than included.
appl – specifies an acceptable source or destination IP application. Format as for
srcappl above.
appl_exclude=true – specifies that the supplied source or destination applications
are excluded rather than included.
recappl – specifies an acceptable recognised IP application. Format as for srcappl
above.
recappl_exclude=true – specifies that the supplied recognised applications are
excluded rather than included.
applid – specifies an acceptable identified application.
<name>
The identified application name; see Device Settings for more
information
<id>
The identified application identifier
applid_exclude=true – specifies that the supplied identified applications are
excluded rather than included.
tos – specifies an acceptable Type-of-Service value.
<prec>
The precedence, in the range 0-7
<tos>
A string of letters indicating which ToS bits must be set or
unset, each letter being one of D, T, R or M for low delay, high
throughput, high reliability and minimise monetary cost
respectively, or d, t, r or m for normal delay, normal
throughput, normal reliability and normal monetary cost; any
bits not specified as set or unset will be disregarded
<prec>%20<tos>
The precedence and ToS as above; %20 being a URL-encoded
space character
tos_exclude=true – specifies that the supplied Type-of-Service values are excluded
rather than included.