Roland XV-5080 Electronic Keyboard User Manual


 
121
Chapter 3 Selecting Output Jacks
Chap.3
Converting to the Various Digital Formats
Digital Output to an ADAT
Connect a DIF-AT, and youll then be able to output to an ADAT.
When Making the XV-5080 the Word Clock Master
fig.RBUS-2.e
Settings
XV-5080 Settings
Master Clock: INTERNAL
Master Freq: 44.1 or 48.0 kHz (set to match the sampling rate of the connected device)
DIF-AT Clk Select:R-BUS
ADAT Settings
CLOCK: DIG
INPUT: DIGITAL
When Making the XV-5080 the Word Clock Slave Settings
XV-5080 Settings
Master Clock: R-BUS
DIF-AT Clk Select:ADAT
ADAT Settings
CLOCK: INT
INPUT: DIGITAL
POWER
OPTICAL
R-BUS DIF-AT
adat
XV-5080
W
W
IN
IN
OUT
OUT
Word Clock
W