Parameter List
System Parameters
SYSTEM General #1 ([SYSTEM/UTILITY]-[F1(General)])(p. 209)
Group Parameter Value
Setup LCD Contrast LCD contrast 110
Patch Remain Patch remain switch OFF, ON
Powerup Mode Power up mode LAST-SET, DEFAULT
Character Style Character Style TYPE14
Rhythm Edit Key Rhythm edit key PANEL, PANEL&MIDI
SCSI Probe Time SCSI probe time 110
Master Level Master level 0127
Tune Master Tune 415.3466.2Hz
Key Shift Key Shift -24+24 semitones
System Tempo Clock Source Clock source INT, MID
Tempo System tempo 20250
SYSTEM General #2 ([SYSTEM/UTILITY]-[F1(General)])(p. 211)
Group Parameter Value
Scale Tune Switch Scale tune switch OFF, ON
PATCH SCALE CB Scale tune CB -64+63
KEY SCALE CB Scale tune CB -64+63
SYSTEM Output ([SYSTEM/UTILITY]-[F2(Outp&EQ)-[F2(Output)])(p. 211)
Group Parameter Value
Digital Interface Master Clock Master Clock INTERNAL/R-BUS/WORD CLOCK IN
Master Freq Master Frequency 44.1/48.0kHz
DIF Control DIF-AT Clk Select DIF-AT Clock select R-BUS/ADAT/DA-88
Output Mix/Parallel Mode Mix/Parallel MIX, PARALLEL
Output Gain Gain Output Gain -12, -6, 0, +6, +12 dB
SYSTEM EQ ([SYSTEM/UTILITY]-[F2(Outp&EQ)-[F2(EQ)])(p. 211)
Group Parameter Value
Output-AD L.F Low Frequency 200/400Hz
L.G Low Gain -15+15
H.F High Frequency 2000/4000/8000Hz
H.G High Gain -15+15
SYSTEM MIDI ([SYSTEM/UTILITY]-[F3(MIDI)])(p. 211)
Group Parameter Value
MIDI Receive Ch Perform Ctrl Ch Performance control channel 116, OFF
Patch/Rhy Rx Ch Patch/Rhythm set receive channel 116
System Exclusive Device ID Device ID number 1732
Receive Sw Receive exclusive switch OFF, ON
MIDI Tx Transmit Edit Data Transmit edit data switch OFF, ON
Stack Mode Stack mode OFF, 28
Number Stack number 18
Rx Switch Program Chg Program Change OFF, ON
Bank Select Receive bank select switch OFF, ON
GM System ON Receive GM-ON exclusive switch OFF, ON
GM2 System ON Receive GM2-ON exclusive switch OFF, ON
GS Reset Receive GS Reset exclusive switch OFF, ON
SYSTEM Control ([SYSTEM/UTILITY]-[F4(Control)])(p. 215)
Group Parameter Value
System Control 1-4 Source System control assign 1-4 OFF, CC0195(except 32), PITCH BEND, AFTERTOUCH