Tektronix vx4380 Drums User Manual


 
Command Descriptions
3–16
VX4380 256-Crosspoint Relay Matrix Module User Manual
ABORt
ABORt
N/A
N/A
N/A
ROUTe:SCAN,
INITiate[:IMMediate],
TRIGger[:SEQuence][:SOURce],
TRIGger[:SEQuence][:IMMediate]
TRIGger[:SEQuence][:COUNt]
TRIGger[:SEQuence][:DELay]
This comand places an initiated scan sequence in the idle state.
The following example defines a scan sequence of 10 relays. The sequence is
aborted after the third relay in the sequence is closed. In this example, module
names m1 and m2 refer to VX4380 Modules. After a scan sequence is aborted,
triggers are no longer accepted by the Option 01 until another INITiate[:IMMedi-
ate] command is received.
Command Response
route:scan
(@m1(1:5),m2(60:64))
Define a scan sequence.
trigger:sequence:
source hold
This command disables the following trigger sources: VXI TTL
triggers, VXI Trigger commands, *TRG command, and IMMedi-
ate triggers. The TRIGger[:SEQuence][:IMMediate] command,
however, overrides this command. It triggers the module and
skips the delay specified in a previously issued TRIGger
[:SEQuence]:DELay command.
initiate:immediate Initiate the scan sequence.
trig Close the first relay in the sequence.
trig Open the first relay and close the second relay in the se-
quence.
Command Syntax
Query Syntax
*RST Value
Limits
Related Commands
Description
Examples