Tektronix vx4380 Drums User Manual


 
Command Descriptions
VX4380 256-Crosspoint Relay Matrix Module User Manual
3–45
SYSTem
SYSTem
:ERRor?
Parameter “y” in these error messages represents the local bus address of the
module that the error message applies to. A value of 1 indicates the module
containing the Option 01 daughter board, a value of 2 indicates the module in the
next slot to the right, and so on.
0,“No error”
–102, “Syntax error; 1 dimensional <channel_spec> invalid for VX4380
module”
–102, “Syntax error; 2 dimensional <channel_spec> invalid for VX4350
module”
–102, “Syntax error; 3 dimensional <channel_spec> invalid for VX43xx
module”
–102, “Syntax error; channel dimension mismatch”
–102, “Syntax error; integer field greater than 10 characters”
–102, “Syntax error; Missing module name”
–102, “Syntax error; Module address not specified”
–102, “Syntax error; Module name already defined”
–102, “Syntax error; Module name length greater than 12 characters”
–102, “Syntax error; Non-contiguous section numbers”
–102, “Syntax error; ROUTe:CONFigure command invalid for VX43xx module”
–102, “Syntax error; ROUTe:DISJoin command invalid for VX43xx module”
–102, “Syntax error; ROUTe:JOIN command invalid for VX43xx module”
–102, “Syntax error; ROUTe:MODE command invalid for VX43xx module”
–102, “Syntax error; Undefined module name”
–102, “Syntax error; Unexpected x detected while ...”
–121, “Invalid character in number”
–123, “Exponent too large”
Command Syntax
Query Response