AW1600 Owner’s Manual
Using the Recall Safe function
8
Using libraries and scene memories
80
You can specify that specific faders or specific channels will be excluded from Recall operations
when the scene is changed either manually or from an external MIDI device. This function is
called “Recall Safe.”
For example, this is convenient if you are performing a mixdown while switching scenes, but want
to control specific channels manually.
1
In the data entry/control section, repeatedly
press the [SCENE] key or hold down the
[SCENE] key and use the CURSOR [ ]/[ ]
keys to access the RCL SAFE page of the
SCENE screen.
1 FADER RECALL SAFE
Here you can select the fader(s) for which recall safe
will be enabled. The fader(s) you select here will not
change even when another scene is recalled. These
buttons correspond to the faders as follows.
•PAD 1–4................Pad channel 1–4 faders
• INPUT 1–8............Input channel 1–8 faders
• TRACK 1–8,
9-10–15-16............Track channel 1–8 and 9/10–15/
16 faders
B ENABLE/DISABLE button
This button switches Fader Recall Safe between
ENABLE and DISABLE states. Move the cursor to
this button and press the [ENTER] key to switch the
display between ENABLE and DISABLE.
C CH RECALL SAFE
Selects the channel(s) for which Recall Safe will be
enabled. Mix parameters of the selected channel(s)
will not change even when another scene is recalled.
The buttons correspond to the following channels.
•PAD.......................All pad channels
• INPUT ...................All input channels
• TRACK..................All track channels
•RTN.......................Return channels 1/2
• ST OUT.................Stereo output channel
2
Select the fader(s) or channel(s) that you
want to set to Recall Safe, and turn the cor-
responding button(s) on (highlighted).
3
If you selected a fader in step 2, move the
cursor to the ENABLE/DISABLE button and
press the [ENTER] key to switch the display
to ENABLE.
Fader or channel Recall Safe has now been enabled.
The selected fader(s) and/or channel(s) will not be
affected by scene recall operations until you change
this setting.
Using the Recall Safe function
1 32
• The settings of the RCL SAFE page are shared by all songs.
HINT