A trigger delay module manages the signals used for triggering envelopes and sequencer.
There are 2 delays, which can function independently, in series or parallel following the setting
on the “mode” selector.
Set to the “off” position, the 2 delays are independent. When their trigger input moves to an
active state, their internal counter is initialized. The output will move to an active state when
their internal counter reaches the value specified by the rotating “time” button. When the
trigger input returns to an inactive state, the output immediately goes not an inactive state.
Set to the “parallel” position, the 2 internal counters start at the same time when the trigger
input of the first delay goes to an active state. Each manages its output in function with its
time setting.
In the series position, the second counter only begins when the output of the first delay moves
to an active state.