ARTURIA – MOOG MODULAR V 2.6 – USER’S MANUAL 89
7.2.2 Resonant filter bank
Filter bank
Gain Sets the band level to positive or negative
Resonance Sets the bandwidth
Connection VCA1-VCA2 Connection of the filter bank to the VCA1 or VCA2 output
Output Gain Sets the output gain
Reset Resets the filter bank
This module allows the equalization of the signal coming from the 2 output amplifiers in
function with the state of the interrupters “VCA11” and “VCA2”.
This equalization is done with the help of the resonant filters and has 14 bands. Each has a
level (amplification and alleviation) and bandwidth setting, excepting the first and last bands,
which are respectively, the low-pass and high-pass filters.
The cut-off frequencies of these filters are fixed at the following values: 80 Hz, 125 Hz, 175
Hz, 250 Hz, 350 Hz, 500 Hz, 700 Hz, 1000 Hz, 1400 Hz, 2000 Hz, 2800 Hz, 4000 Hz, 5600 Hz
and 6400 Hz.
A button allows the resetting of the default values and a rotating button sets the output level
after filtering.
Gain
Resonance
Reset
Connection
VCA1-VCA2
Output gain