Edit mode (EDIT)
● Bend Pitch Control
fig.checksum
Since the GS Bend Pitch Control message has a data
range of 40H–58H (0–24 semitones), we will select
Advanced mode 1, which lets us specify the range.
Since the data format is one byte, we will select
“DT0” (p. 161) when inserting the data.
1. Press the [EDIT] button.
The display will indicate “EDT”.
2. Slightly move the controller to which you want to assign the system exclusive message. In the case of a
button, press that button.
The display will indicate the number of the selected controller.
3. Confirm what’s indicated and press [ENTER].
4. Press the [SYSTEM Ex.] key, and then press the [1] key.
The display will indicate “SE1”.
5. Confirm what’s indicated and press [ENTER].
The display will blink “F0”, which is the first byte (beginning status) of a system exclusive message.
(This cannot be changed.)
6. Confirm what’s indicated and press [ENTER].
7. Use the [4] and [1] keys to input the second byte “41”.
8. Confirm what’s indicated and press [ENTER].
Input the third, fourth and fifth bytes in the same way.
9. Since the sixth byte is the beginning of the checksum calculation area, press the [CHECKSUM] key to specify
this byte as the beginning of the area for which the checksum will be calculated.
10.Confirm what’s indicated and press [ENTER].
11.Input the sixth byte.
12.Since the seventh byte will have “2” in the upper bits and the block number in the lower bits, press [DATA]
three times.
The display will indicate “0BL”.
F0 41 10 42 12 40 2x 10 DATA SUM F7
Address Data Checksum
Block number
1 byte
Checksum calculation region