Roland PCR-30 Musical Instrument User Manual


 
176
MIDI implementation
System exclusive message
The PCR-30/50/80 is able to transmit the following exclusive messages: exclusive
messages assigned to the controllers, Identity Reply, V-LINK messages, and Bulk
Dump.
Universal non-realtime system exclusive
Identity reply
This message will be transmitted when an Identity Request message is received.
Status Data byte Status
F0H 7EH,10H,06H,02H,41H,62H,01H, F7H
00H,00H,00H,01H,00H,00H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal non-realtime message)
10H Device ID (For the PCR-30/50/80, fixed at 10H)
06H Sub ID #1 (General Information)
02H Sub ID #1 (Identity Reply)
41H ID number (Roland)
62H 01H Device family code
00H 00H Device family number code
00H 01H Software revision level
00H 00H :
F7H EOX (End of Exclusive)
V-LINK message
V-LINK ON
Transmitted when entering V-LINK mode.
Status Data byte Status
F0H 41H,10H,00H,51H,12H, F7H
10H,00H,00H,01H,0FH,0FH,51H
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
10H Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H Model ID (V-LINK)
12H Command ID (DT1)
10H 00H 00H Address
01H V-LINK ON
0FH Clip Control Rx. MIDI Ch. (16ch)
0FH Color Control Rx. MIDI Ch. (16ch)
51H Checksum
F7H EOX (End of Exclusive)
V-LINK OFF
Transmitted when exiting V-LINK mode.
Status Data byte Status
F0H 41H,10H,00H,51H,12H, F7H
10H,00H,00H,00H,70H
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
10H Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H Model ID (V-LINK)
12H Command ID (DT1)
10H 00H 00H Address
00H V-LINK OFF
51H Checksum
F7H EOX (End of Exclusive)
Sender Model Name
Transmitted when entering V-LINK mode.
Status Data byte Status
F0H 41H,10H,00H,51H,12H, F7H
10H,71H,00H,45H,44H,49H,52H,4FH,4CH,
20H,50H,43H,52H,00H,3BH
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
10H Device ID (For the PCR-30/50/80, fixed at 10H)
00H 51H Model ID (V-LINK)
12H Command ID (DT1)
aaH Address
10H 71H 00H Data
45H 44H 49H Model name (EDIROL PCR)
52H 4FH 4CH :
20H 50H 43H :
52H 00H :
3BH Checksum
F7H EOX (End of Exclusive)
Data Set 1 DT1 (12H)
Transmitted when you execute Bulk TX in the Bulk mode.
Status Data byte Status
F0H 41H, 10H, 00H, 62H, 12H,
aaH, ddH, ...eeH, sum F7H
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
10H Device ID
00H Model ID #1 (PCR-30/50/80)
62H Model ID #1 (PCR-30/50/80)
12H Command ID (RQ1)
aaH Address
ddH Data
:
:
:
eeH Data
sum Checksum
F7H EOX (End of Exclusive)
* The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump.
* There must be an interval of at least 40 ms between each exclusive message that
is sent.
* Also, you must leave an interval of at least 500 ms after transmitting one set of
bulk dump data.