– 14 –
Level meter value
The level meter values [dB] are indicated as shown below.
MIC SWITCH
This command is used to display the status of the +48V switches of the MIC1/WL1 to MIC6/LINE2 by the 8-bit data.
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
01
MIC6/LINE2 MIC5/LINE1
MIC4 MIC3 MIC2/WL2 MIC1/WL1
When the corresponding bit is ‘1’, the +48V switch is in the ON state. When the corresponding bit is ‘0’, it is in the OFF state.
Bit-6 and bit-7 are fixed all the time.
WL RF
Turning on/off of the RF indicator of the wireless tuner that is installed in the SRP-X700P is indicated by the 8-bit data.
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
010000WL2WL1
RF RF
When the corresponding bit is ‘1’, the RF indicator turns on. When the corresponding bit is ‘0’, the RF indicator turns off.
Bit-2 to bit-7 are fixed all the time.
MIC OVER GAIN
Turning on/off of the OVER GAIN indicators of MIC1/WL1 to MIC6/LINE2 is indicated by the 8-bit data.
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
0 1 MIC6/ MIC5/ MIC4 MIC3 MIC2/ MIC1/
LINE2 LINE1 WL2 WL1
When the corresponding bit is ‘1’, the OVER GAIN turns on. When the corresponding bit is ‘0’, the OVER GAIN turns off.
Bit-6 and bit-7 are fixed all the time.
LINE INPUT OVER GAIN
Turning on/off of the OVER GAIN indicators of LINE3 and 4 is indicated by the 8-bit data.
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
0 1 0 0 0 0 LINE4 LINE3
When the corresponding bit is ‘1’, the OVER GAIN turns on. When the corresponding bit is ‘0’, the OVER GAIN turns off.
Bit-2 to bit-7 are fixed all the time.
LEVEL LEVEL
under -30 30[H] (‘0’)-4 39[H] (‘9’)
-30 31[H] (‘1’)-3 3A[H] (‘:’)
-20 32[H] (‘2’)-2 3B[H] (‘;’)
-15 33[H] (‘3’) -1 3C[H] (‘<’)
-10 34[H] (‘4’)0 3D[H] (‘=’)
-8 35[H] (‘5’)1 3E[H] (‘>’)
-7 36[H] (‘6’) 2 3F[H] (‘?’)
-6 37[H] (‘7’) 3 40[H] (‘@’)
-5 38[H] (‘8’)