FACTORY PRESET : 43[H] 52[H] 53[H] 54[H] ( CRST )
This command is used to return the parameters of the SRP-X700P to the default values when shipped from the factory.
Packet format
43[H] 52[H] 53[H] 54[H] 0D[H]
When communication with the SRP-X700P is established with success, all parameters including scene memories return to the default
state when shipped from the factory.
Caution
When the parameters are returned to the default state when shipped from the factory, all parameters that have been set by users will be
overwritten.
Before starting to execute this command, create backup of the parameter values using the supplied software SRP-X700P Manager.
AUTO MIX EDIT PARAMETER REQUEST: 52[H] 41[H] 4D[H] 50[H] ('RAMP')
This command is used to read respective parameters of the automatic mixer from the SRP-X700P.
Caution
This command is supported by the SRP-X700P firmware versions of 1.20 and higher.
Packet format
52[H] 41[H] 4D[H] 50[H] 0D[H]
Return packet format
When communication with the SRP-X700P is established with success, the parameter is returned together with ACK(41[H]('A')) in the
order shown below.
41[H]"parameter"0D[H]
The parameter is the same as the 14 bytes of the AUTO MIX PARAMETER command.