– 32 –
• INFORMATION (2-129th byte)
Specify the information of the input channels using the ASCII code.
Caution
If number of information characters does not reach the 128 bytes, be sure to fill the blanks with the space (20[H]) so that it becomes 128
bytes all the time.
INFORMATION PARAMETER REQUEST : 52[H] 49[H] 4E[H] 46[H] (‘RINF’)
This command is used to read the information and the power-on setting from the SRP-X700P.
• Packet format
52[H] 49[H] 4E[H] 46[H] 0D[H]
• Return packet format
When communication with the SRP-X700P is established with success, the parameter is returned together with ACK (41[H] (‘A’)) in the
order shown below.
41[H] “parameter” 0D[H]
The parameter is the same as the 129-byte parameter of the INFORMATION command.
LINE 3 INPUT : 43[H] 49[H] 4D[H] 33[H] (‘CIL3’)
This command is used to implement setting up the LINE 3 input channel.
Various setups can be memorized in the scene memories by specifying these scene Nos.
• Packet format
43[H] 49[H] 4D[H] 33[H] “parameter (19 bytes)” 0D[H]
• Parameter
The parameter consists of the 19 bytes all the time in the order as shown in the table below.
When you specify NONE (30[H] ‘0’) as the scene No. in the 1st byte, you can establish the present setup. At the same time, when you
specify the scene No.(31[H] (‘1’) through 44[H] (‘D’)), the parameters of the subsequent 2nd through 19th bytes are written in the scene
memories.
For the method of setting the scene No. and index, refer to the GROUP FADER command (pages 29 and 30).
byte Parameter name byte Parameter name
1st SCENE No. 14th PEQ1 GAIN
2nd-9th INDEX 15th PEQ2 Frequency
10 th TRIM 16th PEQ2 Q
11 th FUNCTION ON/OFF 17th PEQ2 GAIN
12th PEQ1 Frequency 18th GAIN LIMIT LEVEL
13th PEQ1 Q 19th FADER LEVEL