– 47 –
PANEL LOCK : 43[H] 4C[H] 43[H] 4B[H] ( ‘CLCK’ )
This command is used to set the PANEL LOCK.
• Packet format
43[H] 4C[H] 43[H] 4B[H] “parameter” 0D[H]
• Parameter
Specify the setup or release of the PANEL LOCK as the parameter.
Example: When specifying release of the PANEL LOCK.
43[H] 4C[H] 43[H] 4B[H] 40[H] 0D[H] (‘C L C K @ CR’)
PARALLEL I/O : 43[H] 50[H] 49[H] 4F[H] (‘CPIO’)
This command is used to set the functions of the REMOTE PARALLEL terminal.
• Packet format
43[H] 50[H] 49[H] 4F[H] “parameter” 0D[H]
• Parameter
The parameter consists of the 44 bytes all the time in the order as shown in the table below.
byte Parameter name byte Parameter name
1st INPUT1 FUNCTION1 23rd INPUT12 FUNCTION1
2nd INPUT1 FUNCTION2 24th INPUT12 FUNCTION2
3rd INPUT2 FUNCTION1 25th OUTPUT1 FUNCTION1
4th INPUT2 FUNCTION2 26th OUTPUT1 FUNCTION2
5th INPUT3 FUNCTION1 27th OUTPUT2 FUNCTION1
6th INPUT3 FUNCTION2 28th OUTPUT2 FUNCTION2
7th INPUT4 FUNCTION1 29th OUTPUT3 FUNCTION1
8th INPUT4 FUNCTION2 30th OUTPUT3 FUNCTION2
9th INPUT5 FUNCTION1 31st OUTPUT4 FUNCTION1
10th INPUT5 FUNCTION2 32nd OUTPUT4 FUNCTION2
11th INPUT6 FUNCTION1 33rd OUTPUT5 FUNCTION1
12th INPUT6 FUNCTION2 34th OUTPUT5 FUNCTION2
13th INPUT7 FUNCTION1 35th OUTPUT6 FUNCTION1
14th INPUT7 FUNCTION2 36th OUTPUT6 FUNCTION2
15th INPUT8 FUNCTION1 37th OUTPUT7 FUNCTION1
16th INPUT8 FUNCTION2 38th OUTPUT7 FUNCTION2
17th INPUT9 FUNCTION1 39th OUTPUT8 FUNCTION1
18th INPUT9 FUNCTION2 40th OUTPUT8 FUNCTION2
19th INPUT10 FUNCTION1 41st OUTPUT9 FUNCTION1
20th INPUT10 FUNCTION2 42nd OUTPUT9 FUNCTION2
21st INPUT11 FUNCTION1 43rd OUTPUT10 FUNCTION1
22nd INPUT11 FUNCTION2 44th OUTPUT10 FUNCTION2
PANEL
LOCK RELEASE 40[H] ( ‘@’ )
LOCK 42[H] ( ‘B’ )