Sony RS-232C Music Mixer User Manual


 
58
SCENE RECALL BUTTON : 43[H] 52[H] 53[H] 41[H] (CRSA)
This command is used to set the scene No. to be recalled, to the SCENE RECALL A to D buttons on the front of the SRP-X700P.
Packet format
43[H] 52[H] 53[H] 41[H] parameter 0D[H]
Parameter
The parameter consists of the 4 bytes all the time in the order as shown in the table below.
Method of specifying the scene No. is the same as that of the SCENE STORE command.
Example: When you want to set the respective buttons as shown below.
RECALL A : Scene No.1
RECALL B : Scene No.2
RECALL C : Scene No.3
RECALL D : Scene No.4
43[H] 52[H] 53[H] 41[H] 31[H] 32[H] 33[H] 34[H] 0D[H]
(C R S A 1 2 3 4 CR)
byte Parameter name
1st RECALL A SCENE No.
2nd RECALL B SCENE No.
3rd RECALL C SCENE No.
4th RECALL D SCENE No.