50 Agilent E1538A Enhanced Frequency/Totalize/PWM SCP
SENSe:FREQuency:LIMit:LOWer?
[SENSe:]FREQuency:LIMit:LOWer? <channel> returns the lower
frequency limit currently set for <channel>
Parameters
Comments <channel> must be a single channel on an E1538A SCP.
Returned Value: .01667 to 250, The type is float32.
Send with VXIplug&play Function: hpe14XX_cmdReal64_Q(...)
[SENSe:]FUNCtion:CONDition
[SENSe:]FUNCtion:CONDition <
ch_list
> sets the SENSe function to input
the digital state for channels in <ch_list>. See “Reading Static Digital State”
on page 14.
Parameters
Comments The E1538 SCP senses the single bit digital state on each channel
specified by this command.
If the channels specified are not on a digital SCP, an error will be
generated.
Use the INPut:POLarity command to set input logical sense.
Related Commands: INPut:POLarity
*RST Condition: SENS:FUNC:COND and INP:POL NORM for all
digital SCP channels.
Send with VXIplug&play Function: hpe14XX_cmd(...)
Usage See “Reading Static Digital State” on page 14.
To set upper 4-bits of E1538 at SCP position 5 to digital inputs send:
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
channel string 100 - 163 none
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
ch_list string 100 - 163 none